Etek AC 1P+N RCD 40A Type A-MV (Earth Leakage)
R470.35 incl Vat
Etek AC 1P+N RCD 40A Type A-MV (Earth Leakage)
EKL3-40M Electro type RCBO is mainly used for AC 50Hz or 60Hz, rated voltage 230 or below and rated working current 40A or below and immediately cut off power supply once someone suffers from electric shock or leakage current above specified value. The circuit-breaker can also function as overload and short-circuit protection and unfrequented changeover of line under normal condition.
Description
Etek AC 1P+N RCD 40A Type A-MV (Earth Leakage)
ETEK EKL3-40M magnetic type RCBO Residual Current Circuit Breaker with Over and Short Current Leakage Protection RCBO
EKL3-40M magnetic type “Phase line + neutral + leakage “protection circuit breaker is applied to the single-phase residential circuit of 50Hz or 60Hz, rated voltage 230V, to protect leakage, civil electrical overload and short circuit. The product is provided with many advantages such as small size, high breaking capacity, cutting off zero-line, live line at the same time, and leakage protecting in the case of reverse wiring live line. This product complies with IEC61009-1 standards, with advanced international technology.
Technical Data
Etek AC 1P+N RCD 40A Type A-MV (Earth Leakage)
Electrical Features |
|||
Mode | Electromagnetic | ||
Type | A | ||
Rated current In | 6,8,10,13,16,20,25,32,40A | ||
Poles | 1P+N | ||
Rated voltage Ue | 230/240V~ | ||
Insulation voltage Ui | 500V | ||
Rated frequency | 50/60Hz | ||
Rated residual operating current(I△n) | 30,100,300mA | ||
Break time under I△n | ≤0.1s | ||
Rated breaking capacity | 6,000A | ||
Energy limiting class | 3 | ||
Rated impulse withstands voltage (1.5/50) Uimp | 4,000V | ||
Dielectric test voltage at ind.Freq. for 1min | 2kV | ||
Pollution degree | 2 | ||
Thermo-magnetic release characteristic | B, C |
Mechanical Features |
|||
Electrical life | 4,000 Cycles | ||
Mechanical life | 10,000 Cycles | ||
Contact position indicator | Yes | ||
Protection degree | IP20 | ||
Reference temperature for setting of thermal elements | 30℃ | ||
Ambient temperature (with daily average≤35℃) | -5℃~+40℃ | ||
Storage temperature | -25℃~+70℃ |
Installation |
|||
Terminal connection type | Cable/Pin-type busbar/U-type busbar | ||
Terminal size top/bottom for cable | 25mm2 18-3AWG | ||
Terminal size top/bottom for busbar | 25mm2 18-3AWG | ||
Tightening torque | 2.5Nm 22In-lbs | ||
Mounting | On DIN rail EN60715(35mm) by means of fast clip device | ||
Connection | Power supply in both directions |
Dimensions
Circuit Diagram
Etek AC 1P+N RCD 40A Type A-MV (Earth Leakage)
Installation Size
Etek AC 1P+N RCD 40A Type A-MV (Earth Leakage)
For Refrence:
Etek AC 1P+N RCD 40A Type A-MV (Earth Leakage)
RCBO (Residual Current Circuit Breakers with Overcurrent Protection)
A Residual Current Circuit Breaker (RCCB)
RCD (Residual Current Device)
What is a RCBO used for?
RCBOs are commonly used in applications where there is the need to combine protection against overcurrents (overload and short-circuit) and protection against earth leakage currents. RCBOs help in sensing this kind of faults and trip the circuit ensuring complete protection of the people and connected equipment.
What is the difference between a RCD and RCBO?
An RCD is a protective device that will protect a number of circuits, normally at least 5. If it picks up a fault on any of these circuits it will trip cutting the power to every circuit it is protecting. An RCBO is basically exactly the same as an RCD however it protects 1 individual circuit.
Is a RCBO better than a RCD?
RCD Vs. RCBO: What is the Difference? RCDs can protect against electric shocks, residual currents, and earth faults. On the other hand, RCBOs can do what RCDs can do and protect a circuit from short circuits and overload.
When should a RCBO be used?
The primary functions of RCBOs are to ensure protection against earth fault currents, overload, and short circuit currents. It is recommended that an RCBO be attached to each separate circuit, meaning that a fault in one circuit will not affect the functioning of the others.
Can I replace RCD with RCBO?
However, you can meet these specifications and save space on the circuit breaker panel: on some circuits, you can replace two devices (RCD and circuit breaker) with a single device (RCBO). This will protect these circuits against current leaks and overloads at the same time.
Does RCBO replace MCB?
Yes you can use RCBO as a replacement to MCB and RCB. In general, RCBO is basically circuit breaker in addition to residual current device. It provides over current, short circuit as well as earth leakage protection.
What is better to use for home wiring RCCB or RCBO and why?
Installation of RCBO is easier than RCCB. RCBO is designed to optimize the operation, facilitate troubleshooting and reduce inefficiencies and downtime.
How can you tell the difference between a RCCB and RCBO?
RCCB will only identify current leakage from circuit. On the other hand, RCBO can notice over current and current leakage from the circuit. The device recognizes over current in the same manner as MCB does. RCBO is usually utilized as replacement for MCB in consumer unit.
ETEK
Zhejiang ETEK Electrical Technology Co.,Ltd. (abbreviation:ETEK Electric) is a professional manufacturing company dedicated to the research and development, production and sales of low-voltage electrical appliances. The company was established in 2011 and is located in Wenzhou City, Zhejiang Province. The company has an advanced production management system, production process and its products cover power safety products for household, commercial, industrial and similar facilities, such as Miniature circuit breakers (MCB), Residual current device (RCD), Isolating switches, Distribution boxes, Molded case circuit breakers (MCCB), Air circuit breakers (ACB), AC contactors, IoT smart circuit breakers, and Electric vehicle charging facilities (EV Charger), etc.
ETEK Electric is committed to solving customers’ pressures and challenges and creating value for customers. ETEK Electric With rich industry experience and a dynamic, professional and efficient senior team, we can provide customers with the best OEM/ODM services.
ETEK Electric always insists on providing our customers with safe and reliable electrical products. We hope our products can guarantee the power safety of users around the world.
Additional information
Dimensions | 6 × 3 × 8 cm |
---|---|
Brand name |